Investigation of impact of using the ICRP 110 adult reference phantoms and ICRP 103 tissue weighting factors on the radiopharmaceutical’s effective dose

، صفحه 0-0 (1) XML اصل مقاله (270.47 K)
عنوان دوره: اولین دوره بین المللی و بیست و هشتمین دوره ملی (1400)
نویسندگان
چکیده
In this study, the effective dose per unit activity administered was calculated for some of the 99mTc based radiopharmaceuticals by the MIRD method using ICRP biokinetic data, the ICRP 110 adult reference phantoms, and the ICRP 103 tissue weighting factors. The results show that with some exceptions, the calculated effective dose using new phantoms and tissue weighting factors are lower than the ICRP published data. This reduction is significant in some cases and can significantly reduce the collective effective dose of patients.